FPGA COMPONENTS & BOARD MANUFACTURING For research, development & industrial systems

SIDE-BY-SIDE REVIEW

Compare FPGA devices

Review resource differences, package constraints and the fields that still need confirmation.

Select devices (2–4)
Reviewed full part numbers

Showing up to 40 search results plus your selected devices. Search the full catalogue above to find another MPN.

Quote these devices ↗
Parameter / statusXC7K160T-1FBG484IKintex-7XC7K160T-1FBG484CKintex-7
Logic cellsSame162240 logic cellsDS180 ↗ · devicep. 4, Table 6, XC7K160T row; Logic Cells column
Conditions

Vendor metric; not comparable to another architecture's ALMs.

162240 logic cellsDS180 ↗ · devicep. 4, Table 6, XC7K160T row; Logic Cells column
Conditions

Vendor metric; not comparable to another architecture's ALMs.

6-input LUTsSame101400 LUT6DS180 ↗ · derivedp. 4, Table 6, XC7K160T row; note 1; p. 7 CLBs, Slices, and LUTs
Conditions

25350 slices x 4 LUT6 per slice.

101400 LUT6DS180 ↗ · derivedp. 4, Table 6, XC7K160T row; note 1; p. 7 CLBs, Slices, and LUTs
Conditions

25350 slices x 4 LUT6 per slice.

Block RAM capacitySame11700 KbDS180 ↗ · devicep. 4, Table 6, XC7K160T row; Block RAM Max (Kb) column
Conditions

Source unit retained: Kb means kilobits, not kilobytes.

11700 KbDS180 ↗ · devicep. 4, Table 6, XC7K160T row; Block RAM Max (Kb) column
Conditions

Source unit retained: Kb means kilobits, not kilobytes.

36 Kb block RAM blocksSame325 blocksDS180 ↗ · devicep. 4, Table 6, XC7K160T row; Block RAM 36 Kb column; note 3
Conditions

Each fundamental block is 36 Kb; may be configured as two 18 Kb blocks.

325 blocksDS180 ↗ · devicep. 4, Table 6, XC7K160T row; Block RAM 36 Kb column; note 3
Conditions

Each fundamental block is 36 Kb; may be configured as two 18 Kb blocks.

DSP slicesSame600 DSP48E1DS180 ↗ · devicep. 4, Table 6, XC7K160T row; DSP Slices column; note 2
Conditions

DSP48E1 architecture; counts must not be treated as cross-vendor equivalent.

600 DSP48E1DS180 ↗ · devicep. 4, Table 6, XC7K160T row; DSP Slices column; note 2
Conditions

DSP48E1 architecture; counts must not be treated as cross-vendor equivalent.

User I/O in this packageSame285 I/ODS180 ↗ · device-packagep. 4, Table 7, XC7K160T row, FBG484 columns
Conditions

Package-specific user I/O. HR + HP; excludes GT serial channels.

285 I/ODS180 ↗ · device-packagep. 4, Table 7, XC7K160T row, FBG484 columns
Conditions

Package-specific user I/O. HR + HP; excludes GT serial channels.

Serial transceivers in this packageSame4 GTXDS180 ↗ · device-packagep. 4, Table 7, XC7K160T row, FBG484 columns; GTX column
Conditions

Number of channels exposed in this selected device/package; not device-family maximum.

4 GTXDS180 ↗ · device-packagep. 4, Table 7, XC7K160T row, FBG484 columns; GTX column
Conditions

Number of channels exposed in this selected device/package; not device-family maximum.

Package codeSameFBG484UG475 ↗ · packagep. 266, Figure 4-12 title
Conditions

Exact package token; does not establish any full orderable MPN.

FBG484UG475 ↗ · packagep. 266, Figure 4-12 title
Conditions

Exact package token; does not establish any full orderable MPN.

Package ball countSame484 ballsUG475 ↗ · packagep. 266, Figure 4-12; full 22 x 22 bottom-view matrix; Kintex equivalent p. 276 Figure 4-22
Conditions

full 22 x 22 bottom-view matrix; Kintex equivalent p. 276 Figure 4-22

484 ballsUG475 ↗ · packagep. 266, Figure 4-12; full 22 x 22 bottom-view matrix; Kintex equivalent p. 276 Figure 4-22
Conditions

full 22 x 22 bottom-view matrix; Kintex equivalent p. 276 Figure 4-22

Package bodySame23 x 23 mmUG475 ↗ · packagep. 11, Table 1-1; p. 266, Figure 4-12, D/E dimensions
Conditions

Package body width x length; excludes PCB keep-out and component height.

23 x 23 mmUG475 ↗ · packagep. 11, Table 1-1; p. 266, Figure 4-12, D/E dimensions
Conditions

Package body width x length; excludes PCB keep-out and component height.

Ball pitchSame1 mmUG475 ↗ · packagep. 11, Table 1-1; p. 266, Figure 4-12, e dimension
Conditions

Ball-to-ball pitch.

1 mmUG475 ↗ · packagep. 11, Table 1-1; p. 266, Figure 4-12, e dimension
Conditions

Ball-to-ball pitch.

Package terminals / leads (vendor count)Unconfirmed dataNot confirmedNot confirmed
Conditions

Not verified in this bounded review.

Speed gradeSame-1DS180 ↗ · MPNp. 16, Figure 2; Speed Grade legend
Conditions

Retain original ordering code -1 in the literal MPN. Datasheet grade is -1. This is not a single application clock limit.

-1DS180 ↗ · MPNp. 16, Figure 2; Speed Grade legend
Conditions

Retain original ordering code -1 in the literal MPN. Datasheet grade is -1. This is not a single application clock limit.

Junction temperature (Tj)Different-40 to +100 °CDS182 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Industrial (I) row
Conditions

Junction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available.

0 to +85 °CDS182 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) row
Conditions

Junction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available.

Temperature gradeDifferentIndustrial (I)DS182 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Industrial (I) rowCommercial (C)DS182 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) row
Core voltage conditionsUnconfirmed dataNot confirmed
Conditions

Not verified in this review.

Not confirmed
Conditions

Not verified in this bounded review.

Maximum application clockUnconfirmed dataNot confirmed
Conditions

Depends on the application, implementation and operating conditions.

Not confirmed
Conditions

Depends on the application, implementation and operating conditions.

Application powerUnconfirmed dataNot confirmed
Conditions

Depends on the application, implementation and operating conditions.

Not confirmed
Conditions

Depends on the application, implementation and operating conditions.

Minimum junction temperatureDifferent-40 °CDS182 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Industrial (I) row
Conditions

Junction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. Expressed from the same reviewed junction-temperature range; not an additional measurement.

0 °CDS182 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) row
Maximum junction temperatureDifferent100 °CDS182 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Industrial (I) row
Conditions

Junction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. Expressed from the same reviewed junction-temperature range; not an additional measurement.

85 °CDS182 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) row
Temperature referenceSameTjDS182 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Industrial (I) row
Conditions

Junction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. Expressed from the same reviewed junction-temperature range; not an additional measurement.

TjDS182 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) row
Conditions

Junction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available.

Conditional temperature operationUnconfirmed dataNot confirmedNot confirmed
Conditions

Not verified in this bounded review.

Minimum core voltageUnconfirmed dataNot confirmedNot confirmed
Conditions

Not verified in this bounded review.

Nominal core voltageUnconfirmed dataNot confirmedNot confirmed
Conditions

Not verified in this bounded review.

Maximum core voltageUnconfirmed dataNot confirmedNot confirmed
Conditions

Not verified in this bounded review.

Current lifecycleUnconfirmed dataNot confirmed
Conditions

Not verified in this review.

Not confirmed
Conditions

Current lifecycle not verified. Do not apply the V-package discontinuation notice to its G-package replacement.

Available stockUnconfirmed dataNot confirmed
Conditions

Not verified in this review.

Not confirmed
Conditions

No inventory, stock, price or lead-time evidence was reviewed.

Comparison is not replacement approval.

Check pinout, bank voltages, configuration, tool support, timing, thermal design and lifecycle before changing a part. Different vendors’ logic and DSP counts need architecture-specific interpretation.