SIDE-BY-SIDE REVIEW
Compare FPGA devices
Review resource differences, package constraints and the fields that still need confirmation.
Select devices (2–4)
| Parameter / status | XC7K410T-1FFG900CKintex-7 | XC7K410T-1FBG900CKintex-7 |
|---|---|---|
| Logic cellsSame | 406720 logic cellsDS180 ↗ · devicep. 4, Table 6, XC7K410T row; Logic Cells columnConditionsVendor metric; not comparable to another architecture's ALMs. | 406720 logic cellsDS180 ↗ · devicep. 4, Table 6, XC7K410T row; Logic Cells columnConditionsVendor metric; not comparable to another architecture's ALMs. |
| 6-input LUTsSame | 254200 LUT6DS180 ↗ · derivedp. 4, Table 6, XC7K410T row; note 1; p. 7 CLBs, Slices, and LUTsConditions63550 slices x 4 LUT6 per slice. | 254200 LUT6DS180 ↗ · derivedp. 4, Table 6, XC7K410T row; note 1; p. 7 CLBs, Slices, and LUTsConditions63550 slices x 4 LUT6 per slice. |
| Block RAM capacitySame | 28620 KbDS180 ↗ · devicep. 4, Table 6, XC7K410T row; Block RAM Max (Kb) columnConditionsSource unit retained: Kb means kilobits, not kilobytes. | 28620 KbDS180 ↗ · devicep. 4, Table 6, XC7K410T row; Block RAM Max (Kb) columnConditionsSource unit retained: Kb means kilobits, not kilobytes. |
| 36 Kb block RAM blocksSame | 795 blocksDS180 ↗ · devicep. 4, Table 6, XC7K410T row; Block RAM 36 Kb column; note 3ConditionsEach fundamental block is 36 Kb; may be configured as two 18 Kb blocks. | 795 blocksDS180 ↗ · devicep. 4, Table 6, XC7K410T row; Block RAM 36 Kb column; note 3ConditionsEach fundamental block is 36 Kb; may be configured as two 18 Kb blocks. |
| DSP slicesSame | 1540 DSP48E1DS180 ↗ · devicep. 4, Table 6, XC7K410T row; DSP Slices column; note 2ConditionsDSP48E1 architecture; counts must not be treated as cross-vendor equivalent. | 1540 DSP48E1DS180 ↗ · devicep. 4, Table 6, XC7K410T row; DSP Slices column; note 2ConditionsDSP48E1 architecture; counts must not be treated as cross-vendor equivalent. |
| User I/O in this packageSame | 500 I/ODS180 ↗ · device-packagep. 4, Table 7, XC7K410T row, FFG900 columnsConditionsPackage-specific user I/O. HR + HP; excludes GT serial channels. | 500 I/ODS180 ↗ · device-packagep. 4, Table 7, XC7K410T row, FBG900 columnsConditionsPackage-specific user I/O. HR + HP; excludes GT serial channels. |
| Serial transceivers in this packageSame | 16 GTXDS180 ↗ · device-packagep. 4, Table 7, XC7K410T row, FFG900 columns; GTX columnConditionsNumber of channels exposed in this selected device/package; not device-family maximum. | 16 GTXDS180 ↗ · device-packagep. 4, Table 7, XC7K410T row, FBG900 columns; GTX columnConditionsNumber of channels exposed in this selected device/package; not device-family maximum. |
| Package codeDifferent | FFG900UG475 ↗ · packagep. 289, Figure 4-35 titleConditionsExact package token; does not establish any full orderable MPN. | FBG900UG475 ↗ · packagep. 284, Figure 4-30 titleConditionsExact package token; does not establish any full orderable MPN. |
| Package ball countSame | 900 ballsUG475 ↗ · packagep. 289, Figure 4-35; note 4: actual solder ball count = 900Conditionsnote 4: actual solder ball count = 900 | 900 ballsUG475 ↗ · packagep. 284, Figure 4-30; full 30 x 30 bottom-view matrixConditionsfull 30 x 30 bottom-view matrix |
| Package bodySame | 31 x 31 mmUG475 ↗ · packagep. 11, Table 1-1; p. 289, Figure 4-35, D/E dimensionsConditionsPackage body width x length; excludes PCB keep-out and component height. | 31 x 31 mmUG475 ↗ · packagep. 11, Table 1-1; p. 284, Figure 4-30, D/E dimensionsConditionsPackage body width x length; excludes PCB keep-out and component height. |
| Ball pitchSame | 1 mmUG475 ↗ · packagep. 11, Table 1-1; p. 289, Figure 4-35, e dimensionConditionsBall-to-ball pitch. | 1 mmUG475 ↗ · packagep. 11, Table 1-1; p. 284, Figure 4-30, e dimensionConditionsBall-to-ball pitch. |
| Package terminals / leads (vendor count)Unconfirmed data | Not confirmed | Not confirmed |
| Speed gradeSame | -1DS180 ↗ · MPNp. 16, Figure 2; Speed Grade legendConditionsRetain original ordering code -1 in the literal MPN. Datasheet grade is -1. This is not a single application clock limit. | -1DS180 ↗ · MPNp. 16, Figure 2; Speed Grade legendConditionsRetain original ordering code -1 in the literal MPN. Datasheet grade is -1. This is not a single application clock limit. |
| Junction temperature (Tj)Same | 0 to +85 °CDS182 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) rowConditionsJunction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. | 0 to +85 °CDS182 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) rowConditionsJunction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. |
| Temperature gradeSame | Commercial (C)DS182 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) row | Commercial (C)DS182 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) row |
| Core voltage conditionsUnconfirmed data | Not confirmedConditionsNot verified in this review. | Not confirmedConditionsNot verified in this review. |
| Maximum application clockUnconfirmed data | Not confirmedConditionsDepends on the application, implementation and operating conditions. | Not confirmedConditionsDepends on the application, implementation and operating conditions. |
| Application powerUnconfirmed data | Not confirmedConditionsDepends on the application, implementation and operating conditions. | Not confirmedConditionsDepends on the application, implementation and operating conditions. |
| Minimum junction temperatureSame | 0 °CDS182 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) rowConditionsJunction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. Expressed from the same reviewed junction-temperature range; not an additional measurement. | 0 °CDS182 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) rowConditionsJunction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. Expressed from the same reviewed junction-temperature range; not an additional measurement. |
| Maximum junction temperatureSame | 85 °CDS182 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) rowConditionsJunction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. Expressed from the same reviewed junction-temperature range; not an additional measurement. | 85 °CDS182 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) rowConditionsJunction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. Expressed from the same reviewed junction-temperature range; not an additional measurement. |
| Temperature referenceSame | TjDS182 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) rowConditionsJunction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. Expressed from the same reviewed junction-temperature range; not an additional measurement. | TjDS182 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) rowConditionsJunction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. Expressed from the same reviewed junction-temperature range; not an additional measurement. |
| Conditional temperature operationUnconfirmed data | Not confirmed | Not confirmed |
| Minimum core voltageUnconfirmed data | Not confirmed | Not confirmed |
| Nominal core voltageUnconfirmed data | Not confirmed | Not confirmed |
| Maximum core voltageUnconfirmed data | Not confirmed | Not confirmed |
| Current lifecycleUnconfirmed data | Not confirmedConditionsNot verified in this review. | Not confirmedConditionsNot verified in this review. |
| Available stockUnconfirmed data | Not confirmedConditionsNot verified in this review. | Not confirmedConditionsNot verified in this review. |
Check pinout, bank voltages, configuration, tool support, timing, thermal design and lifecycle before changing a part. Different vendors’ logic and DSP counts need architecture-specific interpretation.