SIDE-BY-SIDE REVIEW
Compare FPGA devices
Review resource differences, package constraints and the fields that still need confirmation.
Select devices (2–4)
| Parameter / status | XC7A200T-L1SBG484IArtix-7 | XC7A200T-1FBG484IArtix-7 |
|---|---|---|
| Logic cellsSame | 215360 logic cellsDS180 ↗ · devicep. 3, Table 4, XC7A200T row; Logic Cells columnConditionsVendor metric; not comparable to another architecture's ALMs. | 215360 logic cellsDS180 ↗ · devicep. 3, Table 4, XC7A200T row; Logic Cells columnConditionsVendor metric; not comparable to another architecture's ALMs. |
| 6-input LUTsSame | 134600 LUT6DS180 ↗ · derivedp. 3, Table 4, XC7A200T row; note 1; p. 7 CLBs, Slices, and LUTsConditions33650 slices x 4 LUT6 per slice. | 134600 LUT6DS180 ↗ · derivedp. 3, Table 4, XC7A200T row; note 1; p. 7 CLBs, Slices, and LUTsConditions33650 slices x 4 LUT6 per slice. |
| Block RAM capacitySame | 13140 KbDS180 ↗ · devicep. 3, Table 4, XC7A200T row; Block RAM Max (Kb) columnConditionsSource unit retained: Kb means kilobits, not kilobytes. | 13140 KbDS180 ↗ · devicep. 3, Table 4, XC7A200T row; Block RAM Max (Kb) columnConditionsSource unit retained: Kb means kilobits, not kilobytes. |
| 36 Kb block RAM blocksSame | 365 blocksDS180 ↗ · devicep. 3, Table 4, XC7A200T row; Block RAM 36 Kb column; note 3ConditionsEach fundamental block is 36 Kb; may be configured as two 18 Kb blocks. | 365 blocksDS180 ↗ · devicep. 3, Table 4, XC7A200T row; Block RAM 36 Kb column; note 3ConditionsEach fundamental block is 36 Kb; may be configured as two 18 Kb blocks. |
| DSP slicesSame | 740 DSP48E1DS180 ↗ · devicep. 3, Table 4, XC7A200T row; DSP Slices column; note 2ConditionsDSP48E1 architecture; counts must not be treated as cross-vendor equivalent. | 740 DSP48E1DS180 ↗ · devicep. 3, Table 4, XC7A200T row; DSP Slices column; note 2ConditionsDSP48E1 architecture; counts must not be treated as cross-vendor equivalent. |
| User I/O in this packageSame | 285 I/ODS180 ↗ · device-packagep. 3, Table 5, XC7A200T row, SBG484 columnsConditionsPackage-specific user I/O. HR I/O; excludes serial transceiver channels. | 285 I/ODS180 ↗ · device-packagep. 3, Table 5, XC7A200T row, FBG484 columnsConditionsPackage-specific user I/O. HR I/O; excludes serial transceiver channels. |
| Serial transceivers in this packageSame | 4 GTPDS180 ↗ · device-packagep. 3, Table 5, XC7A200T row, SBG484 columns; GTP columnConditionsNumber of channels exposed in this selected device/package; not device-family maximum. | 4 GTPDS180 ↗ · device-packagep. 3, Table 5, XC7A200T row, FBG484 columns; GTP columnConditionsNumber of channels exposed in this selected device/package; not device-family maximum. |
| Package codeDifferent | SBG484UG475 ↗ · packagep. 265, Figure 4-11 titleConditionsExact package token; does not establish any full orderable MPN. | FBG484UG475 ↗ · packagep. 266, Figure 4-12 titleConditionsExact package token; does not establish any full orderable MPN. |
| Package ball countSame | 484 ballsUG475 ↗ · packagep. 265, Figure 4-11; full 22 x 22 bottom-view matrixConditionsfull 22 x 22 bottom-view matrix | 484 ballsUG475 ↗ · packagep. 266, Figure 4-12; full 22 x 22 bottom-view matrix; Kintex equivalent p. 276 Figure 4-22Conditionsfull 22 x 22 bottom-view matrix; Kintex equivalent p. 276 Figure 4-22 |
| Package bodyDifferent | 19 x 19 mmUG475 ↗ · packagep. 11, Table 1-1; p. 265, Figure 4-11, D/E dimensionsConditionsPackage body width x length; excludes PCB keep-out and component height. | 23 x 23 mmUG475 ↗ · packagep. 11, Table 1-1; p. 266, Figure 4-12, D/E dimensionsConditionsPackage body width x length; excludes PCB keep-out and component height. |
| Ball pitchDifferent | 0.8 mmUG475 ↗ · packagep. 11, Table 1-1; p. 265, Figure 4-11, e dimensionConditionsBall-to-ball pitch. | 1 mmUG475 ↗ · packagep. 11, Table 1-1; p. 266, Figure 4-12, e dimensionConditionsBall-to-ball pitch. |
| Package terminals / leads (vendor count)Unconfirmed data | Not confirmed | Not confirmed |
| Speed gradeDifferent | -1LDS180 ↗ · MPNp. 16, Figure 2; note 1ConditionsRetain original ordering code -L1 in the literal MPN. Datasheet grade is -1L. This is not a single application clock limit. | -1DS180 ↗ · MPNp. 16, Figure 2; Speed Grade legendConditionsRetain original ordering code -1 in the literal MPN. Datasheet grade is -1. This is not a single application clock limit. |
| Junction temperature (Tj)Same | -40 to +100 °CDS181 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Industrial (I) rowConditionsJunction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. | -40 to +100 °CDS181 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Industrial (I) rowConditionsJunction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. |
| Temperature gradeSame | Industrial (I)DS181 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Industrial (I) row | Industrial (I)DS181 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Industrial (I) row |
| Core voltage conditionsUnconfirmed data | Not confirmedConditionsNot verified in this review. | Not confirmedConditionsNot verified in this review. |
| Maximum application clockUnconfirmed data | Not confirmedConditionsDepends on the application, implementation and operating conditions. | Not confirmedConditionsDepends on the application, implementation and operating conditions. |
| Application powerUnconfirmed data | Not confirmedConditionsDepends on the application, implementation and operating conditions. | Not confirmedConditionsDepends on the application, implementation and operating conditions. |
| Minimum junction temperatureSame | -40 °CDS181 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Industrial (I) rowConditionsJunction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. Expressed from the same reviewed junction-temperature range; not an additional measurement. | -40 °CDS181 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Industrial (I) rowConditionsJunction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. Expressed from the same reviewed junction-temperature range; not an additional measurement. |
| Maximum junction temperatureSame | 100 °CDS181 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Industrial (I) rowConditionsJunction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. Expressed from the same reviewed junction-temperature range; not an additional measurement. | 100 °CDS181 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Industrial (I) rowConditionsJunction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. Expressed from the same reviewed junction-temperature range; not an additional measurement. |
| Temperature referenceSame | TjDS181 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Industrial (I) rowConditionsJunction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. Expressed from the same reviewed junction-temperature range; not an additional measurement. | TjDS181 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Industrial (I) rowConditionsJunction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. Expressed from the same reviewed junction-temperature range; not an additional measurement. |
| Conditional temperature operationUnconfirmed data | Not confirmed | Not confirmed |
| Minimum core voltageUnconfirmed data | Not confirmed | Not confirmed |
| Nominal core voltageUnconfirmed data | Not confirmed | Not confirmed |
| Maximum core voltageUnconfirmed data | Not confirmed | Not confirmed |
| Current lifecycleUnconfirmed data | Not confirmedConditionsNot verified in this review. | Not confirmedConditionsNot verified in this review. |
| Available stockUnconfirmed data | Not confirmedConditionsNot verified in this review. | Not confirmedConditionsNot verified in this review. |
Check pinout, bank voltages, configuration, tool support, timing, thermal design and lifecycle before changing a part. Different vendors’ logic and DSP counts need architecture-specific interpretation.