FPGA DEVICES · ENGINEERING · SOURCING Source-linked information. Clear project requirements.

Hard-to-find

ispPAC-POWR1220AT8-01T100I: preserve trim profiles in an EOL purchase

Published · Updated

ispPAC-POWR1220AT8-01T100I is a specific SnPb, 100-pin Lattice Power Manager II order code. A maintenance purchase must preserve both its identity and the board’s programmed trim behavior. The useful output of this guide is a purchasing brief linked to an eight-channel configuration record: what must remain exact, what may change, and which missing facts prevent a responsible alternative review.

Bring the complete BOM line, board revision, schematic, configuration archive, converter part numbers and assembly restrictions. Inventory, price, usable lot quantity and delivery remain to be confirmed by a quotation. The method below is an original document-review aid; no board was powered, programmed, simulated or independently certified for this article.

Read the official electrical datasheet · Open the original affected-order-code workbook · Request 25 units of the exact original MPN

Recover the exact code and the historical withdrawal record

One affected order code, three historical milestonesOriginal timeline for PCN 02A-15 and workbook version 3. The 01T100I affected suffix differs from the 01TN100I potential alternative. Dates are historical milestones, not supply dates.Read every suffixispPAC-POWR1220AT8-01T100I-01TN100IAffectedPotential2015-06-23Notice issued2015-12-23Last-time buy2016-12-30Last shipmentHistorical record · no stock claim
The affected T100I code and TN100I potential alternative remain separate identities. Dates come from the 2015 notice; workbook version 3 is dated 2015-08-12. Identity and historical lifecycle only.

The original affected workbook for PCN 02A-15, version 3 dated 2015-08-12, places ispPAC-POWR1220AT8-01T100I in AffectedOPNs_All, cell C2184. Its row identifies TQFP, 100 leads, SnPb and group 1. Cell E2184 names ispPAC-POWR1220AT8-01TN100I as a potential alternative. Preserve those literal strings in the service BOM: the inserted N is a material distinction that a shortened family description can conceal. Manufacturer workbook, row 2184.

The notice was issued on 2015-06-23; last-time-buy orders were due by 2015-12-23, with shipments through 2016-12-30. Last-time-buy orders were non-cancellable and non-returnable; later orders were subject to the best-effort condition in the notice. These are historical manufacturer milestones. An offer received today needs its own evidence about the offered units and commercial conditions; the old shipment date cannot establish when a seller acquired, stored or can deliver a particular lot. PCN 02A-15, pp. 1–3.

The April 2019 datasheet still prints the original T100I part in its ordering table. That is useful identity evidence, but a later datasheet publication date does not itself rescind the earlier order-code withdrawal. Read the documents by purpose: the ordering table decodes the part; the notice records the dated commercial event; a current quotation describes a proposed transaction. Keep an explicit place for a later revision or continuation agreement if the manufacturer provides one, rather than assuming one exists.

The workbook marks the historical alternative as available, pinout compatible, voltage compatible and backward compatible with a SnPb assembly process. Transcribe these as historical row attributes, together with the workbook version. They are a useful starting point for a change record, not evidence that any offered unit carries the needed programming, that the assembly process is qualified, or that the alternative is currently available. The distinction matters especially when a purchasing system automatically accepts suffix variations.

The Full MPN check looks up an exact complete order code in the reviewed public FPGA.io catalogue. A miss means unconfirmed in that catalogue, not an invalid manufacturer part number. A match does not authenticate an offered lot or approve its use. The tool does not compare two order-code strings or decode their suffixes. For a manual comparison, use the exact-device evidence workflow, preserving the required and offered codes separately and checking their differences against the manufacturer’s literal ordering table.

For another application of the same historical SnPb withdrawal evidence, read the ispPAC-POWR1014-01T48I sourcing case. That 48-pin controller provides related notice and finish-review context. It is a different device, not a recommended replacement for this 100-pin trim controller; its settings and electrical limits cannot populate this board’s worksheet.

Open the complete order-code concept walkthrough (close to hide motion)
Shared original order-code review concept: record both strings, locate the manufacturer source, carry the conditions and save unresolved questions. Not POWR1220 electrical data or a power measurement.
Shared original teaching GIF, displayed at 800 × 450. Its generic labels and any shared example codes are not ispPAC-POWR1220AT8 specifications, programmed setpoints or measured power behavior. The T100I/TN100I ordering context below comes from the cited manufacturer workbook, not from the animation.

Static transcript and application to this exact code:

  1. Record both strings. Keep the required ispPAC-POWR1220AT8-01T100I separate from any offered ispPAC-POWR1220AT8-01TN100I. Do not shorten either to a family name.
  2. Locate the literal source. Read AffectedOPNs_All!C2184 and E2184 in workbook version 3. The first is the affected order code; the second is its historical potential alternative.
  3. Carry the conditions. Trace the T100I/TN100I finish distinction to the manufacturer documents. Review the actual assembly-process restrictions and programmed configuration separately; the shared animation does not establish compatibility.
  4. Save unresolved questions. Retain the original order-code requirement and document whether a finish change is permitted, what assembly evidence is missing and which configuration revision is required. A matching text string does not approve a purchase or a repaired board.

Preserve the trim-control behavior before comparing packages

Preserve the complete trim-control loopConceptual signal flow: common profile selection controls all eight TrimCells, while a selected trim output controls an external converter and its corresponding VMON observes the result. Profile zero mode is a per-cell configuration. Not a schematic or pinout.Trace control and feedbackCommon profile selectionVPS pins or PLDEight TrimCellsProfile 0: mode per cellTRIMn → trim network→ converter trim inputConverter outputCorresponding VMONnClosed-loop mode pairsTRIMn with VMONn.Concept only · not a schematic
Original conceptual trim-control map. Recover the actual resistor network, converter, rail and sense return from the board documents. Datasheet pp. 26–30; conceptual grouping, not a schematic, pinout or footprint.

This device’s distinct maintenance problem is the connection between sequencing and eight analog trim channels. The datasheet describes up to twelve monitored supplies, eight TrimCells and four voltage profiles. The profile selection is common to all TrimCells; profile zero allows a separate operating mode for each cell. Closed-loop operation associates TRIMn with the corresponding VMONn. Datasheet pp. 1–2 and 26–30, including Table 6.

That architecture changes how to collect evidence. Do not record “margin high” as one unexplained global setting. First recover which circuit selects the profile, then record what each populated channel does in every profile. A profile can be shared while the intended rail values differ. Name the converter, the load rail, the sense point and the configuration revision in the same row, so a later reviewer can follow the path without reconstructing it from unrelated files.

For each profile-zero channel, establish whether the design uses a saved DAC value, an I²C-loaded value or closed-loop trim. The datasheet distinguishes saved registers from volatile runtime state, and describes startup handling for the latter. The practical implication is that possessing a programming archive may still leave a missing host-software dependency. Ask which firmware revision writes the trim register, what event permits the converter to start, and where the intended write order is documented. Mark missing answers as unresolved.

Separate the controller’s trim-pin voltage from the external converter’s output voltage. The interface resistor network and the converter’s trim characteristic connect those two quantities. A familiar number beside a DAC register is therefore insufficient evidence for the voltage at an FPGA, processor or memory load. Recover the converter documentation and the actual resistor values before deriving a trim transfer function. If a resistor has been substituted during repair, preserve that change in the same record.

As an original review method, trace one populated channel end to end before copying the format across all eight. Begin at the specified load-rail net, follow the sense connection back to VMONn, find the controlling TRIMn network, and locate the matching configuration fields. Compare names and revisions at each step. A mismatch is an actionable document issue even before any measurement occurs; a consistent paper trail is still only preparation for a controlled engineering evaluation.

Do not import the rail voltages drawn in the manufacturer’s application examples into the board worksheet. They demonstrate a function, not the values programmed on this assembly. Similarly, a family-level accuracy headline does not establish total error at a load across the board’s temperature, load transients, converter tolerance and sense routing. The worksheet deliberately asks for the allowed rail window and its own source, rather than deriving an acceptance limit from a marketing summary.

Check grade 01, supply domains and package evidence separately

Separate supply domains from the grade-01 gate-driver rangeOriginal range diagram shows recommended VCCD and VCCA 2.8 to 3.96 V, VCCINP 2.25 to 5.5 V, and VCCJ 2.25 to 3.6 V. A separate panel identifies grade 01 HVOUT as 6 to 10 V, which is not a regulated load rail.Keep voltage domains apartRecommended supplies at pins06 VVCCD /VCCA2.8–3.96 VVCCINP2.25–5.5 VVCCJ2.25–3.6 V01 grade: HVOUT 6–10 VGate-driver programming rangeNot a regulated load supplySource scope: datasheet pp. 6, 53
Original voltage-domain diagram. Grade 01 HVOUT describes the high-voltage gate-driver option; it does not specify the load-rail voltage. Datasheet recommended conditions p. 6 and ordering description p. 53; not absolute maximum ratings.
Source-scoped identity and electrical checkpoints; these are not a full design qualification.
CheckpointDocumented value or conditionLocator and interpretation
01 grade6–10 V HVOUTDatasheet p. 53, Part Number Description; grade-specific gate-driver range, not a load-rail output specification.
T100I identity100-pin conventional TQFP; industrial −40 to +85 °CDatasheet p. 53; SnPb identity additionally comes from workbook row 2184.
VCCD / VCCA2.8 V minimum; 3.96 V maximumDatasheet p. 6, recommended operating conditions, at supply pins.
VCCINP2.25 V minimum; 5.5 V maximumDatasheet p. 6, recommended input-logic supply domain.
VCCJ2.25 V minimum; 3.6 V maximumDatasheet p. 6, recommended JTAG supply domain.
Package outline / pin assignmentSeparate source drawingsDatasheet p. 52 mechanical outline; p. 54 package pin assignment; neither supplies a qualified PCB footprint.

The ordering description explicitly distinguishes grade 01 from grade 02. A general family diagram mentioning a higher driver voltage should not overwrite the full MPN’s grade. Preserve the grade on the enquiry and on any proposed alternative comparison. Treat a different grade as a documented design change until the relevant driver configuration, external switch and operating conditions have been reviewed. Datasheet pp. 6, 52–54.

Build a supply-domain map from the schematic instead of treating “3.3 V device” as a universal interface rule. The supply used for general inputs and the supply used for JTAG have their own documented ranges and reference conditions. Include the programming connector, its voltage reference and any external adapter in that map. A maintenance plan that lists the main supply alone can miss the interface used to restore the replacement’s configuration.

The datasheet’s pin-description footnotes also carry board-level conditions, including VCCD/VCCA and ground connections, the APS programming arrangement, sense returns and open-drain pull-ups. Read those notes against the actual netlist before turning the electrical table into a checklist result. A table of ranges cannot answer whether an external pull-up is present, where it is connected or what a disconnected sense return would do. Those remain board-specific questions. Pin Descriptions and footnotes, pp. 3–6.

Mechanical identity needs three distinct records: the manufacturer’s package outline, the electrical pin assignment, and the PCB library land pattern used by the assembly. Compare their orientation, numbering and revision references. Do not substitute an illustrative package picture for one of those records. For a repaired board, add the assembly drawing and any process restriction that governs finish, cleaning, inspection or rework; the EOL workbook’s historical flag does not supply those local process details.

The Manufacturing file package check can help list the available BOM, fabrication, placement and assembly documents. Use it to expose absent deliverables, then attach the actual revisions to the change record. A complete file list is useful coordination evidence; it does not establish the correctness of a pin mapping or the suitability of a soldering process.

Build an eight-channel record and a bounded power-on plan

Use a channel-by-profile matrix to expose missing configurationOriginal blank matrix has eight TrimCell rows and four voltage-profile columns. Blank cells mean evidence is not supplied. The shared selector does not remove the need to record each channel mode and converter mapping.One selector, eight rail recordsProfile →0123TRIM1TRIM2TRIM3TRIM4TRIM5TRIM6TRIM7TRIM8Blank = evidence not suppliedConcept worksheet · no setpoints shown
An empty profile matrix is an evidence gap, not a zero-volt command. The static worksheet gives the fields for all eight channels. Original engineering worksheet concept, not a programmed image.

The worksheet below is the article’s original static engineering output. Complete it from the archived design rather than from an assumed default configuration. For a channel that is unused, write “unused” and cite the source showing its intended treatment. For an unknown channel, retain “not supplied.” These states must remain different: an unknown mapping cannot safely become an unused channel through a spreadsheet cleanup.

Original eight-channel recovery worksheet. Replace “not supplied” with a document locator, an explicitly unused status, or an open issue.
ChannelConverter, rail and VMON mappingProfiles 0 / 1 / 2 / 3 and control authorityEvidence and unresolved limits
TRIM1 / VMON1Not supplied: converter MPN; rail net; sense return; trim resistor network.Not supplied: profile-0 mode; saved codes; runtime writes; selector source.Not supplied: allowed rail window; board revision; drawing and configuration revision.
TRIM2 / VMON2Not supplied: converter MPN; rail net; sense return; trim resistor network.Not supplied: profile-0 mode; saved codes; runtime writes; selector source.Not supplied: allowed rail window; board revision; drawing and configuration revision.
TRIM3 / VMON3Not supplied: converter MPN; rail net; sense return; trim resistor network.Not supplied: profile-0 mode; saved codes; runtime writes; selector source.Not supplied: allowed rail window; board revision; drawing and configuration revision.
TRIM4 / VMON4Not supplied: converter MPN; rail net; sense return; trim resistor network.Not supplied: profile-0 mode; saved codes; runtime writes; selector source.Not supplied: allowed rail window; board revision; drawing and configuration revision.
TRIM5 / VMON5Not supplied: converter MPN; rail net; sense return; trim resistor network.Not supplied: profile-0 mode; saved codes; runtime writes; selector source.Not supplied: allowed rail window; board revision; drawing and configuration revision.
TRIM6 / VMON6Not supplied: converter MPN; rail net; sense return; trim resistor network.Not supplied: profile-0 mode; saved codes; runtime writes; selector source.Not supplied: allowed rail window; board revision; drawing and configuration revision.
TRIM7 / VMON7Not supplied: converter MPN; rail net; sense return; trim resistor network.Not supplied: profile-0 mode; saved codes; runtime writes; selector source.Not supplied: allowed rail window; board revision; drawing and configuration revision.
TRIM8 / VMON8Not supplied: converter MPN; rail net; sense return; trim resistor network.Not supplied: profile-0 mode; saved codes; runtime writes; selector source.Not supplied: allowed rail window; board revision; drawing and configuration revision.

Alongside the channel rows, keep one global record for the board revision, complete controller MPN, configuration archive name and hash, host firmware revision, profile-selection source, programming route and acceptance-document revision. Store original code files separately from derived notes. A checksum can show that the file used later is the same file collected now; it does not show that the file belongs to this board or that its contents were independently validated.

For threshold review, create a second line per monitored rail containing the nominal target, the allowed low and high limits, the selected comparator thresholds, the filter choice and the source of each value. This is a suggested review format, not a claim about the installed settings. No threshold is supplied here for this exact assembly. If the load’s permitted window or the programmed threshold is missing, stop that comparison rather than filling the field from another board using the same controller.

As a clearly hypothetical arithmetic exercise, a rail specified by its own design owner as 1.00 V ±5% has a stated window of 0.95–1.05 V. That subtraction and addition do not select comparator settings: a real comparison still needs sensing error, programmed threshold accuracy, transient allowance and the load’s applicable conditions. These numbers are not recommendations for an FPGA rail, values read from this device, or evidence that a trim profile has been programmed.

Use the existing Power-on test planning checklist only after collecting those references. Enter your real Board and revision and select the real Build stage. In Full FPGA MPN, enter the actual FPGA mounted on that board; the POWR controller is not an FPGA, so do not enter its MPN in that field. If there is no applicable FPGA or its identity is unknown, keep the static worksheet and do not fabricate a value to force a tool run.

In Official rail / sequencing references and revision, enter the controller MPN, datasheet revision 2.0, the actual board power specification and configuration revision. Add the profile selector, the channel-map record and unresolved threshold references in concise text. In Accessible test points, enter only documented rail and return test points, with their schematic locators. Remove the tool’s example references; an example test-point name is not evidence of access on the physical assembly.

After Run check, the expected output is a staged review draft with open limits, not a set of invented electrical limits or a controlled power supply. Inspect the result against the input references and retain its text report if it accurately represents the intended board. The tool does not program the controller, exercise the trim loop, measure a rail or approve a procedure. Its actual interactive run and report for your board remain to be performed; this article does not claim a tool run on a real assembly.

Without JavaScript, use the same collected information to write five headings in a local review record: inspection, initial rail review, sequencing, configuration and functional evaluation. Under each, list the governing document, available observation point, required limit and open issue. This fallback preserves the planning task while leaving the actual method, instruments and acceptance limits to the board’s documented procedure. Missing limits remain visible in both paths.

Turn the record into an exact-part request or a finish-change review

Separate an exact-part quotation from an alternative-change recordOriginal flow starts with exact MPN and quantity 25, then asks whether a finish change is permitted. Exact sourcing keeps 01T100I; a change record names 01TN100I and must resolve configuration and assembly differences. No branch proves availability.Name the requested routeRequired: -01T100IQuantity: 25 unitsFinish changepermitted?No / unknownYesExact sourcingKeep -01T100ILot evidenceChange record-01TN100IReview differencesBoth routes need source evidence,terms and a configuration record.Decision aid · no availability claim
Keep the exact-part request and a permitted finish-change review as separate records. Retain the original order code. Original decision aid; no stock, compatibility or qualification claim.

For an exact-only maintenance requirement, request ispPAC-POWR1220AT8-01T100I, quantity 25 units and state that a proposed suffix change needs separate review. Include required delivery date, destination, permitted lot splits, traceability expectations and any condition or date-code restrictions that actually apply. Ask the supplier to identify the offered complete MPN and provide the evidence supporting the offer. Keep quoted quantity, lot identity, price and delivery conditions tied to that specific quotation.

For a permitted finish-change route, retain the original requirement and open a separate comparison for ispPAC-POWR1220AT8-01TN100I. Cite workbook row 2184 and the historical compatibility flags, then attach the configuration, converter mapping and assembly constraints collected above. Do not silently replace the BOM text. A proposed alternative has its own identity, source status and unresolved checks; the historical recommendation does not remove those questions.

Use the BOM completeness check to prepare a consistent purchasing line if this is part of a larger maintenance list. Keep the requested device count separate from the number of assembled boards and from any spare quantity. The hard-to-find notice directory supports another exact-code search, but its records are historical lifecycle evidence rather than a stock catalogue.

A board-level rebuild has a different input package. Provide the BOM, schematic, placement and assembly files, PCB fabrication data, stack-up, programming archive and the relevant acceptance requirements through the PCB and PCBA project preparation route. State whether supply, programming and evaluation work are requested. If the configuration archive or trim network is missing, name that gap in the project brief so it can shape the proposed work instead of disappearing inside a generic assembly quote.

Further evaluation is reasonable when the complete identity, configuration provenance, channel mapping and permitted change scope are documented. Resolve a wrong grade, an unapproved finish change or a conflicting rail mapping before treating an offer as an engineering solution. Current authorized supply, lot authenticity, remaining service life, actual programmed values and board performance remain unverified here. This dossier is AI-assisted document preparation and review, not human engineering sign-off.

Next action: Request price and lead time for 25 × ispPAC-POWR1220AT8-01T100I. Review the homepage fields and add the board and configuration requirements before submitting your own enquiry. Stock, price and delivery require confirmation.

Prepared 2026-11-10. Primary evidence: PCN 02A-15; affected workbook version 3, 2015-08-12; FPGA-DS-02051 revision 2.0, April 2019. Original diagrams and worksheet by FPGA.io’s AI-assisted editorial workflow. No physical, simulation, programming or independent human engineering test is claimed.

Back to Hard-to-find →

Source addresses and citation trail

Full source addresses are retained below. Read each citation with its document revision, page, table and applicability conditions above.

  1. https://www.latticesemi.com/view_document?document_id=17601
  2. https://www.latticesemi.com/view_document?document_id=51135
  3. https://edge.sitecorecloud.io/latticesemi9e32-latticesemi06bb-prod9ecc-d341/media/Project/Lattice/LatticeSemi/Documents/ProductChangeNotification/PCN15/PCN02A15SnPbandSelectMatureFamilyDiscontinuance.pdf?sc_lang=en