SIDE-BY-SIDE REVIEW
Compare FPGA devices
Review resource differences, package constraints and the fields that still need confirmation.
Select devices (2–4)
| Parameter / status | XC7A200T-L1FBV676IArtix-7 | XC7K325T-1FBG676CKintex-7 |
|---|---|---|
| Logic cellsDifferent | 215360 logic cellsDS180 ↗ · devicep. 3, Table 4, XC7A200T row; Logic Cells columnConditionsVendor metric; not comparable to another architecture's ALMs. | 326080 logic cellsDS180 ↗ · devicep. 4, Table 6, XC7K325T row; Logic Cells columnConditionsVendor metric; not comparable to another architecture's ALMs. |
| 6-input LUTsDifferent | 134600 LUT6DS180 ↗ · derivedp. 3, Table 4, XC7A200T row; note 1; p. 7 CLBs, Slices, and LUTsConditions33650 slices x 4 LUT6 per slice. | 203800 LUT6DS180 ↗ · derivedp. 4, Table 6, XC7K325T row; note 1; p. 7 CLBs, Slices, and LUTsConditions50950 slices x 4 LUT6 per slice. |
| Block RAM capacityDifferent | 13140 KbDS180 ↗ · devicep. 3, Table 4, XC7A200T row; Block RAM Max (Kb) columnConditionsSource unit retained: Kb means kilobits, not kilobytes. | 16020 KbDS180 ↗ · devicep. 4, Table 6, XC7K325T row; Block RAM Max (Kb) columnConditionsSource unit retained: Kb means kilobits, not kilobytes. |
| 36 Kb block RAM blocksDifferent | 365 blocksDS180 ↗ · devicep. 3, Table 4, XC7A200T row; Block RAM 36 Kb column; note 3ConditionsEach fundamental block is 36 Kb; may be configured as two 18 Kb blocks. | 445 blocksDS180 ↗ · devicep. 4, Table 6, XC7K325T row; Block RAM 36 Kb column; note 3ConditionsEach fundamental block is 36 Kb; may be configured as two 18 Kb blocks. |
| DSP slicesDifferent | 740 DSP48E1DS180 ↗ · devicep. 3, Table 4, XC7A200T row; DSP Slices column; note 2ConditionsDSP48E1 architecture; counts must not be treated as cross-vendor equivalent. | 840 DSP48E1DS180 ↗ · devicep. 4, Table 6, XC7K325T row; DSP Slices column; note 2ConditionsDSP48E1 architecture; counts must not be treated as cross-vendor equivalent. |
| User I/O in this packageSame | 400 I/OUG475 ↗ · device-packagep. 16, Table 1-8, XC7A200T row, FBG676/FBV676 shared columnConditionsHR user I/O only; excludes serial transceiver channels. | 400 I/ODS180 ↗ · device-packagep. 4, Table 7, XC7K325T row, FBG676 columnsConditionsPackage-specific user I/O. HR + HP; excludes GT serial channels. |
| Serial transceivers in this packageDifferent resource definitions | 8 GTP channelsUG475 ↗ · device-packagep. 12, Table 1-3, XC7A200T row, FBG676/FBV676 shared columnConditionsChannels bonded out in this exact device/package; a blank or dash is never read as zero. | 8 GTXDS180 ↗ · device-packagep. 4, Table 7, XC7K325T row, FBG676 columns; GTX columnConditionsNumber of channels exposed in this selected device/package; not device-family maximum. |
| Package codeDifferent | FBV676UG475 ↗ · packagep. 268, Figure 4-14, shared FBG676/FBV676 drawing, titleConditionsExact V-package token printed in the shared drawing and historical MPN; not renamed to its replacement package. | FBG676UG475 ↗ · packagep. 268, Figure 4-14 titleConditionsExact package token; does not establish any full orderable MPN. |
| Package ball countSame | 676 ballsUG475 ↗ · packagep. 268, Figure 4-14, shared FBG676/FBV676 drawing; full 26 x 26 bottom-view matrixConditionsfull 26 x 26 bottom-view matrix | 676 ballsUG475 ↗ · packagep. 268, Figure 4-14; full 26 x 26 bottom-view matrix; Kintex equivalent p. 279 Figure 4-25Conditionsfull 26 x 26 bottom-view matrix; Kintex equivalent p. 279 Figure 4-25 |
| Package bodySame | 27 x 27 mmUG475 ↗ · packagep. 268, Figure 4-14, shared FBG676/FBV676 drawing, D/E dimensionsConditionsPackage body width x length, not die dimensions, height or PCB keep-out. | 27 x 27 mmUG475 ↗ · packagep. 11, Table 1-1; p. 268, Figure 4-14, D/E dimensionsConditionsPackage body width x length; excludes PCB keep-out and component height. |
| Ball pitchSame | 1 mmUG475 ↗ · packagep. 268, Figure 4-14, shared FBG676/FBV676 drawing, e dimensionConditionsBall-to-ball pitch. | 1 mmUG475 ↗ · packagep. 11, Table 1-1; p. 268, Figure 4-14, e dimensionConditionsBall-to-ball pitch. |
| Package terminals / leads (vendor count)Unconfirmed data | Not confirmedConditionsNot verified in this bounded review. | Not confirmedConditionsNot verified in this bounded review. |
| Speed gradeDifferent | -1LDS180 ↗ · MPNp. 16, Figure 2; note 1ConditionsRetain original ordering code -L1 in the literal MPN. Datasheet grade is -1L. This is not a single application clock limit. Family-specific low-power electrical conditions are in DS181 p. 1; voltage and application timing are not inferred. | -1DS180 ↗ · MPNp. 16, Figure 2; Speed Grade legendConditionsRetain original ordering code -1 in the literal MPN. Datasheet grade is -1. This is not a single application clock limit. |
| Junction temperature (Tj)Different | -40 to +100 °CDS181 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Industrial (I) rowConditionsJunction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. | 0 to +85 °CDS182 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) rowConditionsJunction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. |
| Temperature gradeDifferent | Industrial (I)DS181 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Industrial (I) row | Commercial (C)DS182 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) row |
| Core voltage conditionsUnconfirmed data | Not confirmedConditionsNot verified in this bounded review. | Not confirmedConditionsNot verified in this bounded review. |
| Maximum application clockUnconfirmed data | Not confirmedConditionsDepends on the application, implementation and operating conditions. | Not confirmedConditionsDepends on the application, implementation and operating conditions. |
| Application powerUnconfirmed data | Not confirmedConditionsDepends on the application, implementation and operating conditions. | Not confirmedConditionsDepends on the application, implementation and operating conditions. |
| Minimum junction temperatureDifferent | -40 °CDS181 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Industrial (I) row | 0 °CDS182 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) row |
| Maximum junction temperatureDifferent | 100 °CDS181 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Industrial (I) row | 85 °CDS182 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) row |
| Temperature referenceSame | TjDS181 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Industrial (I) rowConditionsJunction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. | TjDS182 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) rowConditionsJunction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. |
| Conditional temperature operationUnconfirmed data | Not confirmedConditionsNot verified in this bounded review. | Not confirmedConditionsNot verified in this bounded review. |
| Minimum core voltageUnconfirmed data | Not confirmedConditionsNot verified in this bounded review. | Not confirmedConditionsNot verified in this bounded review. |
| Nominal core voltageUnconfirmed data | Not confirmedConditionsNot verified in this bounded review. | Not confirmedConditionsNot verified in this bounded review. |
| Maximum core voltageUnconfirmed data | Not confirmedConditionsNot verified in this bounded review. | Not confirmedConditionsNot verified in this bounded review. |
| Current lifecycleUnconfirmed data | Not confirmedConditionsThis exact V-package MPN is listed in XCN20011 as an affected discontinued product. The current lifecycle field is not refreshed from a current source. | Not confirmedConditionsCurrent lifecycle not verified. Do not apply the V-package discontinuation notice to its G-package replacement. |
| Available stockUnconfirmed data | Not confirmedConditionsNo inventory, stock, price or lead-time evidence was reviewed. | Not confirmedConditionsNo inventory, stock, price or lead-time evidence was reviewed. |
Check pinout, bank voltages, configuration, tool support, timing, thermal design and lifecycle before changing a part. Different vendors’ logic and DSP counts need architecture-specific interpretation.