FPGA COMPONENTS & BOARD MANUFACTURING For research, development & industrial systems

SIDE-BY-SIDE REVIEW

Compare FPGA devices

Review resource differences, package constraints and the fields that still need confirmation.

Select devices (2–4)
Reviewed full part numbers

Showing up to 40 search results plus your selected devices. Search the full catalogue above to find another MPN.

Quote these devices ↗
Parameter / statusXC7A200T-1SBG484CArtix-7XC7A200T-1FBG484CArtix-7
Logic cellsSame215360 logic cellsDS180 ↗ · devicep. 3, Table 4, XC7A200T row; Logic Cells column
Conditions

Vendor metric; not comparable to another architecture's ALMs.

215360 logic cellsDS180 ↗ · devicep. 3, Table 4, XC7A200T row; Logic Cells column
Conditions

Vendor metric; not comparable to another architecture's ALMs.

6-input LUTsSame134600 LUT6DS180 ↗ · derivedp. 3, Table 4, XC7A200T row; note 1; p. 7 CLBs, Slices, and LUTs
Conditions

33650 slices x 4 LUT6 per slice.

134600 LUT6DS180 ↗ · derivedp. 3, Table 4, XC7A200T row; note 1; p. 7 CLBs, Slices, and LUTs
Conditions

33650 slices x 4 LUT6 per slice.

Block RAM capacitySame13140 KbDS180 ↗ · devicep. 3, Table 4, XC7A200T row; Block RAM Max (Kb) column
Conditions

Source unit retained: Kb means kilobits, not kilobytes.

13140 KbDS180 ↗ · devicep. 3, Table 4, XC7A200T row; Block RAM Max (Kb) column
Conditions

Source unit retained: Kb means kilobits, not kilobytes.

36 Kb block RAM blocksSame365 blocksDS180 ↗ · devicep. 3, Table 4, XC7A200T row; Block RAM 36 Kb column; note 3
Conditions

Each fundamental block is 36 Kb; may be configured as two 18 Kb blocks.

365 blocksDS180 ↗ · devicep. 3, Table 4, XC7A200T row; Block RAM 36 Kb column; note 3
Conditions

Each fundamental block is 36 Kb; may be configured as two 18 Kb blocks.

DSP slicesSame740 DSP48E1DS180 ↗ · devicep. 3, Table 4, XC7A200T row; DSP Slices column; note 2
Conditions

DSP48E1 architecture; counts must not be treated as cross-vendor equivalent.

740 DSP48E1DS180 ↗ · devicep. 3, Table 4, XC7A200T row; DSP Slices column; note 2
Conditions

DSP48E1 architecture; counts must not be treated as cross-vendor equivalent.

User I/O in this packageSame285 I/ODS180 ↗ · device-packagep. 3, Table 5, XC7A200T row, SBG484 columns
Conditions

Package-specific user I/O. HR I/O; excludes serial transceiver channels.

285 I/ODS180 ↗ · device-packagep. 3, Table 5, XC7A200T row, FBG484 columns
Conditions

Package-specific user I/O. HR I/O; excludes serial transceiver channels.

Serial transceivers in this packageSame4 GTPDS180 ↗ · device-packagep. 3, Table 5, XC7A200T row, SBG484 columns; GTP column
Conditions

Number of channels exposed in this selected device/package; not device-family maximum.

4 GTPDS180 ↗ · device-packagep. 3, Table 5, XC7A200T row, FBG484 columns; GTP column
Conditions

Number of channels exposed in this selected device/package; not device-family maximum.

Package codeDifferentSBG484UG475 ↗ · packagep. 265, Figure 4-11 title
Conditions

Exact package token; does not establish any full orderable MPN.

FBG484UG475 ↗ · packagep. 266, Figure 4-12 title
Conditions

Exact package token; does not establish any full orderable MPN.

Package ball countSame484 ballsUG475 ↗ · packagep. 265, Figure 4-11; full 22 x 22 bottom-view matrix
Conditions

full 22 x 22 bottom-view matrix

484 ballsUG475 ↗ · packagep. 266, Figure 4-12; full 22 x 22 bottom-view matrix; Kintex equivalent p. 276 Figure 4-22
Conditions

full 22 x 22 bottom-view matrix; Kintex equivalent p. 276 Figure 4-22

Package bodyDifferent19 x 19 mmUG475 ↗ · packagep. 11, Table 1-1; p. 265, Figure 4-11, D/E dimensions
Conditions

Package body width x length; excludes PCB keep-out and component height.

23 x 23 mmUG475 ↗ · packagep. 11, Table 1-1; p. 266, Figure 4-12, D/E dimensions
Conditions

Package body width x length; excludes PCB keep-out and component height.

Ball pitchDifferent0.8 mmUG475 ↗ · packagep. 11, Table 1-1; p. 265, Figure 4-11, e dimension
Conditions

Ball-to-ball pitch.

1 mmUG475 ↗ · packagep. 11, Table 1-1; p. 266, Figure 4-12, e dimension
Conditions

Ball-to-ball pitch.

Package terminals / leads (vendor count)Unconfirmed dataNot confirmedNot confirmed
Speed gradeSame-1DS180 ↗ · MPNp. 16, Figure 2; Speed Grade legend
Conditions

Retain original ordering code -1 in the literal MPN. Datasheet grade is -1. This is not a single application clock limit.

-1DS180 ↗ · MPNp. 16, Figure 2; Speed Grade legend
Conditions

Retain original ordering code -1 in the literal MPN. Datasheet grade is -1. This is not a single application clock limit.

Junction temperature (Tj)Same0 to +85 °CDS181 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) row
Conditions

Junction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available.

0 to +85 °CDS181 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) row
Conditions

Junction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available.

Temperature gradeSameCommercial (C)DS181 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) rowCommercial (C)DS181 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) row
Core voltage conditionsUnconfirmed dataNot confirmed
Conditions

Not verified in this review.

Not confirmed
Conditions

Not verified in this review.

Maximum application clockUnconfirmed dataNot confirmed
Conditions

Depends on the application, implementation and operating conditions.

Not confirmed
Conditions

Depends on the application, implementation and operating conditions.

Application powerUnconfirmed dataNot confirmed
Conditions

Depends on the application, implementation and operating conditions.

Not confirmed
Conditions

Depends on the application, implementation and operating conditions.

Minimum junction temperatureSame0 °CDS181 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) row
Conditions

Junction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. Expressed from the same reviewed junction-temperature range; not an additional measurement.

0 °CDS181 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) row
Conditions

Junction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. Expressed from the same reviewed junction-temperature range; not an additional measurement.

Maximum junction temperatureSame85 °CDS181 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) row
Conditions

Junction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. Expressed from the same reviewed junction-temperature range; not an additional measurement.

85 °CDS181 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) row
Conditions

Junction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. Expressed from the same reviewed junction-temperature range; not an additional measurement.

Temperature referenceSameTjDS181 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) row
Conditions

Junction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. Expressed from the same reviewed junction-temperature range; not an additional measurement.

TjDS181 ↗ · gradep. 3, Table 2 Recommended Operating Conditions (continued); Tj Commercial (C) row
Conditions

Junction temperature Tj, not ambient temperature. Apply only to a literal MPN with the corresponding grade; not a claim all grades are available. Expressed from the same reviewed junction-temperature range; not an additional measurement.

Conditional temperature operationUnconfirmed dataNot confirmedNot confirmed
Minimum core voltageUnconfirmed dataNot confirmedNot confirmed
Nominal core voltageUnconfirmed dataNot confirmedNot confirmed
Maximum core voltageUnconfirmed dataNot confirmedNot confirmed
Current lifecycleUnconfirmed dataNot confirmed
Conditions

Not verified in this review.

Not confirmed
Conditions

Not verified in this review.

Available stockUnconfirmed dataNot confirmed
Conditions

Not verified in this review.

Not confirmed
Conditions

Not verified in this review.

Comparison is not replacement approval.

Check pinout, bank voltages, configuration, tool support, timing, thermal design and lifecycle before changing a part. Different vendors’ logic and DSP counts need architecture-specific interpretation.